<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-04 10-55-54
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
97.30 MHz 5/5, 77 dBuV YLESUOMI
Pilot RDS Phase Difference
7.1 kHz 3.8 kHz 69 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 66 kHz 19000 3,8000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,5 dBr 4,03 dBr 5,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLESUOMI" 6203 2 (Affairs) 1 0 1 1 10:55, 4.03.2025
RT
"BANANARAMA - Love in the first degree "
AF EON
95.6, 97.3, 98.4, 98.6, 98.9, 99.2, 102.5 MHz 6202, 6207, 6205, 6201
FM Scope Max at: 66 kHz MIN: 10 kHz % above 76 kHz: 3,8000 Acquired: 2025/03/04 10.54.51 Total samples: 19000 Equivalent time: 0:15:50 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 5,4 dBr MIN: 2,5 dBr AVE: 4,03 dBr % above 12,2 dBr: 0,0 Last value: 5,3 dBr (2025/03/04 10.54.51) 10.42 10.44 10.46 10.48 10.50 10.52 10.54 0 2 4 6 Pm [dBr]